Prouduct Details:·Model:TC-80K II Smart
·Brand:TOPCITY
·Habitat:TOPCITY
·Size:8 CH
Main Technical Specifications:
1、Thermocouple: K-type thermocouple
2、Sampling interval:0.05sec---600sec Set with software
3、Record data:120000 point/channel, Can record 256 sets profile
4、Resolution: 0.1℃
5、Temperature measuring range: -100—500℃ / 0--1200℃
6、Temperature measuring accuracy: ±1.0℃
7、Total power: ≤100mW
8、Operating voltage:3.6VDC, rechargeable battery
9、Dimensions: 208(L)×75(W)×19(H)mm
10、Insulation box Dimensions:252(L)×88(W)×30(H)mm
11、Start Mode : Manual, specified time or specified temperature
12、Record mode: Monitor/Record
13、Connection mode:RS232/USB
14、Software version: e-DataPro 2.0
Standard Composition:
1. Thermal profiler 2. Insulation box
3. Temperature test line 4. Data download line
5. Charger 6. Hi-temp adhesive tape
7. Software CD 8. “+” screwdriver 9. Tweezers
10. Insulated gloves 11. Hi-temp tine wire
12. Scissors 13. Instrument box
14. User Manual 15. Acceptance Certificate
Software Setup and data analysis:
Product information setup
Machine parameter setup
Solder information setup
PWI
Peak Temp,Times of overtop the Temp
Times of between Temp(Reflow)
Slope of between Temp(Reflow)
Slope of between Times(Wave)
Horizontal line and Vertical line setting
Ramp Slope、Ramp Peak Temp ,Wave Peak Temp